Component root-cause analysis / predictive deep-dive
AI mode: ON Synthetic demonstration data — not operational
Aircraft TJ-1026 · Tejas Mk1 · No. 124 Sqn 'Bisons' · AFS Marut · Western Air Command
Component APU Starter Med · predicted failure mode: Brush & bearing wear
← Back to dashboard
Model risk score 57.2/100 predictive maintenance model
Predicted RUL 23d remaining useful life
Health index 42/100 telemetry-derived
Model confidence 92% evidence density
Open snags (tail) 0 unscheduled, open
Aircraft status Operational 388 flt hrs · 18y old
AI root-cause analysis
Generating AI analysis…

Predicted failure mode

Brush & bearing wear — leading signals: start-time creep, current spikes.

See the Predictive model tab for the substantiating data points and the Maintenance & spare tab for history and the prescriptive action.

Health degradation & failure projection

telemetry-derived health index · signals: start-time creep, current spikes

Why — model risk drivers

Feature attribution — substantiating data points

contributions sum to the 57.2/100 risk score
Risk driverWeightSeverityContributionSubstantiating evidence
Health-index deficit 30% 58% 17.4 pts health 42/100
Failure imminence 28% 62% 17.3 pts ~23d to predicted failure
Recent unscheduled snags 12% 75% 9.0 pts 3 unscheduled events on tail
Component criticality 14% 60% 8.4 pts Med
Airframe age 5% 72% 3.6 pts 18 yrs (inducted 2008)
Cumulative duty (flight hrs) 8% 11% 0.9 pts 388 flight hrs
Spare exposure 3% 20% 0.6 pts 3 on hand, lead 27d
🔒 Source: components · maintenance_events · aircraft · spares — model: gradient-weighted risk attribution · governed & traceable

Maintenance activity — TJ-1026

scheduled vs unscheduled events per month

This component — APU Starter

3 events
DateTypeSeverityStatusDowntime
2026-05-08Scheduled Low Closed 41.9h
2026-02-20Scheduled Low Closed 12.0h
2025-08-10Unscheduled Med Closed 8.8h

Full aircraft history

9 events
DateComponentTypeSevStatusDT
2026-05-20Oxygen RegulatorSched High Closed 85.2h
2026-05-08APU StarterSched Low Closed 41.9h
2026-03-01Oxygen RegulatorUnsch Med Closed 50.1h
2026-02-20APU StarterSched Low Closed 12.0h
2026-01-29Oxygen RegulatorSched Low Closed 16.0h
2025-08-10APU StarterUnsch Med Closed 8.8h
2025-03-27Cockpit Display UnitSched Low Closed 24.3h
2025-02-19Cockpit Display UnitUnsch Med Closed 15.5h
2025-01-31Engine Turbine ModuleSched Low Closed 76.1h

Lead-time history

12 months · current 27d

Stock on hand vs reorder

current 3 · reorder 5

Required spare & prescriptive action

Required spare
APU Starter
on hand 3 · reorder 5 · lead 27d · High
Stock is at/below reorder and lead time has risen to 27 dayspre-position APU Starter at AFS Marut now to avoid an AOG when the component is pulled.

The same chain is visible fleet-wide on the diagnostic drill-down.

Monthly receipts & consumption

MonthLead timeOn handReceivedConsumed
2025-0719d25 43
2025-0820d21 44
2025-0919d18 42
2025-1019d19 22
2025-1118d15 95
2025-1219d13 85
2026-0121d13 12
2026-0226d11 01
2026-0324d9 21
2026-0427d8 22
2026-0529d5 73
2026-0627d3 03
🔒 Source: spares · spares_history · consumption · governed & traceable