Component root-cause analysis / predictive deep-dive
AI mode: ON Synthetic demonstration data — not operational
Aircraft SB-1095 · Su-30MKI · No. 130 Sqn 'Rhinos' · AFS Nabhomani · Central Air Command
Component Generator Control Unit Med · predicted failure mode: Voltage-regulation instability
← Back to dashboard
Model risk score 64.4/100 predictive maintenance model
Predicted RUL 14d remaining useful life
Health index 40/100 telemetry-derived
Model confidence 88% evidence density
Open snags (tail) 1 unscheduled, open
Aircraft status Operational 2304 flt hrs · 12y old
AI root-cause analysis
Generating AI analysis…

Predicted failure mode

Voltage-regulation instability — leading signals: bus voltage excursions.

See the Predictive model tab for the substantiating data points and the Maintenance & spare tab for history and the prescriptive action.

Health degradation & failure projection

telemetry-derived health index · signals: bus voltage excursions

Why — model risk drivers

Feature attribution — substantiating data points

contributions sum to the 64.4/100 risk score
Risk driverWeightSeverityContributionSubstantiating evidence
Failure imminence 28% 77% 21.5 pts ~14d to predicted failure
Health-index deficit 30% 60% 18.0 pts health 40/100
Component criticality 14% 60% 8.4 pts Med
Recent unscheduled snags 12% 50% 6.0 pts 2 unscheduled events on tail
Cumulative duty (flight hrs) 8% 64% 5.1 pts 2,304 flight hrs
Spare exposure 3% 100% 3.0 pts 2 on hand, lead 45d
Airframe age 5% 48% 2.4 pts 12 yrs (inducted 2014)
🔒 Source: components · maintenance_events · aircraft · spares — model: gradient-weighted risk attribution · governed & traceable

Maintenance activity — SB-1095

scheduled vs unscheduled events per month

This component — Generator Control Unit

2 events
DateTypeSeverityStatusDowntime
2026-05-26Unscheduled Med Open 23.7h
2026-03-28Scheduled Med Closed 14.8h

Full aircraft history

7 events
DateComponentTypeSevStatusDT
2026-05-26Generator Control UnitUnsch Med Open 23.7h
2026-03-28Generator Control UnitSched Med Closed 14.8h
2025-10-05Environmental Control PackSched Med Closed 30.4h
2025-03-03Radar Power SupplySched Med Closed 7.2h
2025-02-09Fuel Control UnitSched Low Closed 82.4h
2024-10-31Radar Power SupplyUnsch Low Closed 5.3h
2024-06-26Cockpit Display UnitSched Low Closed 32.1h

Lead-time history

12 months · current 45d

Stock on hand vs reorder

current 2 · reorder 5

Required spare & prescriptive action

Required spare
Generator Control Unit
on hand 2 · reorder 5 · lead 45d · Med
Stock is at/below reorder and lead time has risen to 45 dayspre-position Generator Control Unit at AFS Nabhomani now to avoid an AOG when the component is pulled.

The same chain is visible fleet-wide on the diagnostic drill-down.

Monthly receipts & consumption

MonthLead timeOn handReceivedConsumed
2025-0739d17 22
2025-0838d17 12
2025-0937d15 32
2025-1040d13 42
2025-1141d14 12
2025-1242d11 01
2026-0141d10 23
2026-0239d10 62
2026-0344d6 85
2026-0442d4 31
2026-0543d3 01
2026-0645d2 02
🔒 Source: spares · spares_history · consumption · governed & traceable